ENGINE ELECTRICAL CIRCUITS
BATTERIES (2)
·
Two 6volt automotive lead-acid batteries.
·
Connected in series for combined voltage of 12-volts.
·
Negative side of circuit connected by cable to ground at clutch pedal stop.
·
Positive side of circuit connected by cable to starter solenoid switch battery terminal.
·
Store electrical energy to operate electrical system components.
STARTER SOLENOID SWITCH
·
Mounted to starter motor.
·
Battery terminal connected by cable to positive side of battery circuit and output terminal of ac generator.
·
B terminal connected by strap to motor positive terminal.
·
S terminal connected by wires to starter switch negative terminal and hydraulic pump stroke control solenoid valve
positive terminal.
·
Grounded by mounting hardware to starter motor housing.
·
Engages starter motor spur gear with flywheel ring gear and energizes starter motor to crank engine, when starter
switch is pushed and range shift lever is in neutral.
TA242687
1-21
|
|