![]() ![]() TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
Starting Motor Inoperative - Continued.
386-488
10. Test for continuity between
starter relay ground and
starter solenoid.
a. Place battery disconnect
switch in OFF position.
b. Disconnect both larger
gage wires from starter
relay.
0006 00-32
|
|