Feed Motor and Gearbox Assembly
Up
TM-5-3820-239-15 Drill Pneumatic Drifter: Boom-Type; Crawler-Mounted; Self-Propelled (Ingersoll-Rand Models CM150A/D475A and CM225/D475A) Manual
Next
Remote Control Valve Repair

Section II. DIRECT SUPPORT MAINTENANCE INSTRUCTIONS
7-17. Remote Control Valve Repair
(13) Remove washer (20) and O-ring (21) from each
a. Disassembly.
end of body (8). Discard O-rings.
(1) Remove valve (see paragraph 7-1).
(14) Remove retainer (22) and O-ring (23) from
(2) Unscrew and remove lever (1) from knuckle
each end of body (8). Discard O-rings.
(2).
(15) Remove plunger (11) from body (8).
(3) Remove boot (3) and clip (4) from lever cap (5).
(16) Remove O-ring (24) from each end of plunger
(4) Remove screw (6) from lever cap (5).
(11). Discard O-rings.
(5) Remove four screws (7) securing lever cap (5)
(17) Remove two O-rings (25) from middle of
to body (8).
plunger (11). Discard O-rings.
(6) Partially remove lever cap (5) from body (8),
(18) Remove two bushings (26) from body (8).
then remove clip (9) from link assembly (10). Separate link
(19) Remove two O-rings (27) from each bushing
assembly from plunger (11), then fully remove lever cap.
(26). Discard O-rings.
(7) Remove knuckle (2) and link assembly (10)
b. Inspection.
from lever cap (5).
Warning: Dry cleaning solvent P-D-680 is toxic and
(8) Remove O-ring (12) from screw (6). Discard
flammable. Wear protective gloves and use in a well venti-
O-ring.
lated area. Avoid contact with skin, eyes, and clothes and
(9) Remove four screws (13) securing spring cap
do not breathe vapors. Do not use near open flame or ex-
(14) to body (8). Remove spring cap.
cessive heat. The flash point is 100-138 degrees F (38-50
(10) Remove cage (15) from detent (16) or spring
degrees C). If you become dizzy while using cleaning sol-
cap (14), being careful not to lose six balls (17). Balls are
vent, get fresh air immediately and get medical aid. If con-
packed in grease and should stay inside cage.
tact with eyes is made, wash your eyes with water and get
medical aid immediately.
(11) Remove spring clip (18) from detent (16).
(1) Clean all parts with dry cleaning solvent and
(12) Remove pin (19) securing detent (16) to plung-
dry thoroughly.
er (11). Remove detent from plunger.