TM 5-2590-512-13&P SECTION V.  UNIT MAINTENANCE PROCEDURE 4-28.  Shaft Bearing and Seal Replacement. This task covers: a.  Removal b.  Installation Initial Setup Tools: Equipment Conditions: General Mechanic's Tool Kit. Output shaft removed (see para.  4-26). 5180-00-177-7033. Materials and Parts: Seals, Bearings cones, Bearing cups, GAA Grease, Rags, P-D-680 Solvent. a.  Removal 1. Insert  drift  (1)  into  hub  (2)  thru  bottom  hub  opening.    Gently  tap around metal exposed edge of upper seal (3) until seal comes out. Remove upper bearing cup and cone (4). 2. Insert drift (1) into hub (2) thru top hub opening. Gently tap around metal   exposed   edge   of   lower   seal   (5)   until   seal   comes   out. Remove bottom bearing cup and cone (6). b.  Installation WARNING Dry cleaning solvent P-D-680 is toxic and flammable.  Wear protective goggles, face mask, and gloves and use only in a well ventilated area.  Avoid contact with skin, eyes, and clothes,  and  don't  breathe  vapor.    Do  not  use  near  open flame   or   excessive   heat.      The   flashpoint   for   Type   dry cleaning solvent is 1000F (380 C) and for Type II is 1400 F. (600- C).  If you become dizzy while using cleaning solvent, get  fresh  air  immediately  and  get  medical  aid.    If  contact with  eyes  is  made,  flush  eyes  with  water  and  get  medical aid immediately. 1. Carefully clean output shaft (7) and inside of hub (2).  Inspect for any   cracks,   breaks,   bends,   visible   wear,   or   general   defects. Replace any defective parts. 2. Install lower bearing cup and lower bearing cone (6) in hub (2). 3. Use cylinder shape tool on lower seal (5) to apply uniform force and tap lower seal in place in hub (2). 4. Install upper bearing cup and upper bearing cone (4) in hub (2). 5. Use cylinder shape tool on upper seal (3) surface to apply uniform force and tap seal in place in hub (2). FOLLOW ON TASKS Install Output Shaft (para 4-26). END OF TASK 4-29

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing