TM 9-2320-364-20-2      2-1063 (1)   Disconnect connector MC23. (2)   Set multimeter select switch to volts dc. (3)   Connect positive (+) multimeter lead to ether start solenoid harness connector MC23, terminal A. (4)   Connect negative (–) multimeter lead to a known good ground. (5)   Turn ON ENGINE switch (TM 9-2320-364-10). (6)   Press and hold the ether start switch while checking for voltage. (a)   If there are not 22 to 28 vdc present, turn OFF ENGINE switch, and go to Step 5 of this Fault. (b)   If there are 22 to 28 vdc present, wire 1926 is OK. (7)   Turn OFF ENGINE switch. VOLTAGE TEST (1)   Set multimeter select switch to ohms. (2)   Is there continuity between solenoid connector MC23, terminal B and a known good ground? (a)   If there is no continuity present, repair wire 1435 ( see schematic Fig 2-23) or notify DS Maintenance. (b)   If there is continuity present, replace ether start solenoid (Para 4-18). (3)   Connect connector MC23 to ether start solenoid connector. CONTINUITY TEST Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry or tools contact positive electrical circuits, a direct short may result.  Damage to equipment, injury or death to personnel may occur.

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business