TM 9-2320-364-20-2      2-1861 (1)   Check air lines 2488 and 2536 for crimps (see schematic Fig 2-44). (a)   If there are crimps in air lines, replace air lines (Para 12-36). (b)   If there are no crimps in air lines, perform Steps (2) and (3) below. (2)   Apply service brakes (TM 9-2320-364-10). (3)   Check fittings and air lines 2488, 2536 for leaks (see schematic Fig 2-44). (a)   If fittings or air lines are leaking, perform Step (6) below and tighten/replace fittings and/or replace air lines (Para 12-36). (b)   If there are no leaks, fittings and air lines are OK.  Perform Step (4) below. (4)   Check service relay valve No. 1 for leaks. (a)   If service relay valve No. 1 leaks, perform Step (6) below and replace valve (Para 12-13). (b)   If there are no leaks, perform Step (5) below. (5)   Check air chambers for leaks. (a)   If air chamber leaks, perform Step (6) below and replace air chamber (Para 12-9). (b)   If there are no leaks, perform Step (6) below. (6)   Release service brakes. VISUAL/AUDIBLE INSPECTION Wear safety goggles when performing leakage tests on valves.  Failure to do so may result in serious eye injury due to high pressure air. (1)   Remove six screws, locknuts and glove box.  Discard locknuts. (2)   Disconnect air line 2488 from cab air manifold. (3)   Connect 0 to 160 psi (0-1103 kPa) gage to air line 2488. (4)   Apply service brakes (TM 9-2320-364-10). (a)   If there are not 125 4 psi (861 28 kPa) present at air line 2488, perform Steps (5) through (7) below and replace brake treadle valve (Para 12-4). (b)   If there are 125 4 psi (861 28 kPa) present at air line 2488, brake treadle valve is OK. (5)   Release service brakes. (6)   Remove gage and connect air line 2488 to cab air manifold. (7)   Install glove box, six screws and locknuts. BRAKE TREADLE VALVE TEST

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business