TM 1-1740-204-13&P
g. High Pressure Relief Valve (9)
The adjustable high pressure relief valve (9) has a range of 2,000 psi to 4,000 psi. It is provided to limit the high
pressures generated in the booster pump system and has a mechanical stop limiting the maximum pressure to
4,200 psi.
h. Low Pressure Filter (10)
The low pressure filter (10) separates water and particulate contaminants from the shop air source and has an
automatic mechanical drain to remove the contaminants from the filter bowl.
1-8