GENERATOR AND REGULATOR - CONTINUED
Up
TM-5-3805-254-20-2 Truck Dump 20-Ton 6x4 On-Off Highway 71 000 GVW IHC Model F-5070 (CCE) Manual
Next
GENERATOR PULLEY

TM 5-3805-254.20-2 GENERATOR AND REGULATOR - CONTINUED ACTION LOCATION ITEM REMARKS ADJUSTMENT NOTE Adjust generator if ampere output is not within 10 percent of rated output stamped on generator. Go to Troubleshooting (page 2-43). 17. Connector body (1) Voltage adjustment a. Take out. cap (2) b. Rotate 90-degrees clockwise to raise ampere output, and counterclockwise to lower ampere output. c. Put in. NOTE FOLLOW-ON MAINTENANCE: 1.  Connect battery ground cable (page 2424). 2.  Close right side hood panel (page 2-424). TASK ENDS HERE TA244130 2-670