2.11 HOPPER LIFT SYSTEM
Up
TM-5-3895-373-34 Paving Machine Bituminous Material Crawler Mounted Diesel Engine Driven Manual
Next
Table 2-6.  Hopper Lift System Troubleshooting - Continued

TM 5-3895-373-34 Table 2-6.  Hopper Lift System Troubleshooting - Continued. MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1. HOPPER FAILS TO OPERATE. WARNING Hydraulic  oil  can  be  moderately  flammable  and  can  be  an  irritant  to  skin,  eyes,  and respiratory  system.    Avoid  prolonged  exposure.    Eye  protection  and  rubber  gloves must be worn when working with hydraulic oil. Step 1. Open right access door per TM 5-3895-373-10.  Install hydraulic system tester at outlet (1) for flow test per TM 9-4940-468-14.  Check flow rate at power-beyond valve outlet (I) with hopper wing lift in operation.  Measure flow rate at 2475 +25 psi (17 066 +172 kPa). If flow is present, at 2475 ±25 psi (17 066 ±172 kPa) replace power-beyond valve.  Refer to paragraph 2.44. Step 2. Install hydraulic system tester at outlet (2) for flow test per TM 9-4940-468-14.  Check flow rate at stack valve outlet (2) to return manifold with hopper wing lift in operation. If flow is present below 2450 psi (16 893 kPa), replace stack relief valve per paragraph 2.44. If  no  flow  is  present  below  2450  psi  (16  893  kPa),  refer  to  MALFUNCTION  4.    AUXILIARY HYDRAULIC SUPPLY TO VIBRATION AND CYLINDER CIRCUITS FAULTY. Step 3. Disconnect  hydraulic  system  tester  per  TM  9-4940-468-14.    Reconnect  all  hydraulic  lines.    Close right access door per TM 5-3895-373-10. 2-41