Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: USA Display Flag
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Setting the Span
Up
TM-5-3895-374-24-1 Paving Machine Bituminous Material: Crawler Mounted Diesel Engine Driven Manual
Next
Set Dead Load

TM 5-3895-374-24-1 SECTION IV - PARAMETERS Note In order to change the parameters of the indicator you must be in the Calibration mode (flashing ’[’ the far left digit - see Calibration Section III). *In the following list of Parameters,  the Factory Preset value will be indicated in (  ). Parameter No. Description 1. Reload Factory Values. Calibrates the scale with commonly values.  When you have selected this function, press (1) [ENTER].  Note this  will clear previous calibration. 2. Decimal Point Position.  (0) 0,  1,  2,  3 or 4.  Select to correspond graduation size.  e.g.  set to 1  for .5 grads, set to 0 for 10 KG grads. 3. Graduation Size.   (2 LB/1 KG) Select one from this table: LB .0002, .0005, .0010, .002, .005, .010,  .02, .05, .10, .2,  .5,  1,  2.  5, 10, 20.  50, 100, 200. KG .0001, .0002,  .0005, .001, .002, .005, .01, .02, .05, .1, .2,  .5, 1, 2, 5, 10, 20, 50, 100. 4. Overweight. (15002 LB/6805 XG) Must be less than 5000 displayed  graduations and greater than 1 graduation. 5. Motion Window. (4 LB/2 KG) Enter a weight to determine motion sensitivity.  A typical value is 2 times graduation size.  Note the motion window met automatically when the grad (Parameter 3) is changed. 6. Power On Units.   (0 = LB) Selects the displayed  units active when power is applied to the indicator. 1 selects KG;  0 selects LB. 7. Change Displayed Units.  (LB) Allows you to calibrate in pounds 0 kilograms. Each time this parameter I selected.  the displayed units will toggle. 8. USA  Display Flag. (0) The USA  display flag can be set to ’0’ o ’1’.  Setting  the flag  to ’0’ gives  the standard  display.  Setting the flag to ’ 1 causes the following display changes a) Dead Zeros -   The  active  digit will always be displayed at zero, i.e. for a grad size of 10, the zero display will be ’00’. b) Dead Zeros behind decimal points - For grad sizes of .0010 LB .0005 KG, .010 LB/.005 KG, .1LB/.05 KG  and  1.0 LB/.5 KG the extra dead zero shown in the LB mode will be blanked This is only effective fo decimal positions greater than ‘O’. The USA flag must be set to '1'  for the indicator to be 'Legal for Trade" in the USA. 9. Power On Reset Warning.    (1) The  Power On Reset Flag allows designation os the power push to zero mode.    If this flag is set to '0', the indicator will start with its push to zero register cleared and the weight display active.    If this flag is  met to '1', then the weight display will show 'rrrrrr' on power up until an initial push to zero occurs.  To be legal for trade, this flag must be set to '1'. Page 3-66

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing