TM 5-3895-374-24-1 GP470FA [20] Display Setpoint  -  This function is  used for setting a setpoint value.  The setpoint is a signal sent from the output port of the indicator to open or close a gate or to turn on or off some external device. To store a setpoint value press [20] [SELECT] then enter the desired setpoint value and press [SELECT] again.  For example: to set a setpoint at 1000 Press 120]1SELECTI, Press [10001[SELECTI To check the setpoint value that you have entered, press [20] [SELECT] again. Note: This setpoint operates on the displayed weight, regardless of the scale channel selected. Channel 1 Setpoint. Channel 2 Setpoint. Channel 3 Setpoint. These 3 setpoints are only available with the optional 100- 174 setpoint board. These setpoints are independent and are operative regardless of which weight channel Is being displayed. Setpoint values are stored in a similar manner to that described above. Note. When checking the values for these setpoints make sure you press [CLEAR] after each value is displayed, otherwise the next selection (i.e. [22] [SELECT] will be interpreted as the value entry for the previously selected setpoint (i.e. [21] [SELECT]). SECTION II - INSTALLATION AND WIRING Physical Installation The DF2000 indicator can be located wherever convenient.  It is not advisable to locate the indicator where it would be exposed to direct sunlight, excessive mechanical abuse or moisture. Power Requirements The DF2000 desk-top model has a self-contained DC power supply that requires only a source of 115V-120V AC.  If you are using your own power supply, please note that the indicator requires a 12 VDC input.  It will operate satisfactorily over an input range from 11 VDC to 17 VDC.  Although the indicator has built-in voltage regulation, it is most desirable that the input voltage be stable  over  the stated input range.  Ensure that an inline fuse is installed and is of the correct size - AGCI (1 amp fast blowing).  No other fuse should be used. (page 3-57)

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing