CONFIGURATION RECORD SHEET
Up
TM-5-3895-374-24-1 Paving Machine Bituminous Material: Crawler Mounted Diesel Engine Driven Manual
Next
RECOMMENDED SPARE PARTS

TM 5-3895-374-24-1 GP467FB SET UP LOWER DISPLAY UPPER GROUP (FUNCTION)          DISPLAY TUNING PROP BAND 15 RATE MIN 0.00 RESET RPM 1 00 LOCKOUT NONE SH RAMP SP RAMP DISABLE AUTOTUNE AT ENABLE DISABLE ALGORITHM CONT ALG PID A OUT ALG POSITION INPUT 1 DECIMAL X X X X UNITS DEG F OR DEG C IN 1 TYPE JTCLOW IN 1 HIGH 770 F OR 410C IN 1 LOW 20 F OR -7 C BIAS IN l 00 FILTER 1 0 BURNOUT UP POWER FREQ (60 or 50 Hertz as specified on order) CONTROL PID SETS 1 ONLY SP SOURCE 1 LOCAL RATIO 1 0 BIAS 0 POWER UP MANUAL SP HI LIMIT 770 F OR 410 C SP LO LIMIT 20 F OR -7 C ACTION REVERSE OUT HI LIM 100.0 OUT LO LIM 00 DROPOFF 0 DEADBAND 4.0 FAILSAFE 0.0 PB OR GAIN PB PCT MIN OR RPM RPM OPTIONS AUX OUT DISABLE REMOTESW NONE COMRS422 COMSTATE DISABLE (page 3-19)