UDC3000 MICROPROCESSOR TEMPERATURE CONTROLLER
Up
TM-5-3895-374-24-1 Paving Machine Bituminous Material: Crawler Mounted Diesel Engine Driven Manual
Next
CONFIGURATION RECORD SHEET

TM 5-3895-374-24-1 GP467FB Fig 4-UDC3000 Temperature Controller 1. UPPER DISPLAY: Normally shows Process Variable temperature Also displays parameter values or selections when in the Configuration Mode. 2. LOWER DISPLAY: Shows value of Set Point, amount of deviation from Set Point or Motor position in % Also displays function groups and parameters when in the Configuration Mode. 3. ALARM 1 INDICATOR: Lights when Alarm 1 setting has been exceeded 4. RSP INDICATOR: Lights when remote Set Point or 2nd Set Point has been selected. 5. OUT1, OUT2 INDICATORS: Shows when Temperature Controller output relay Is energized to drive the Burner Control Motor. 6. UNITS INDICATOR: Indicates degrees F or degrees C is being displayed. 7. AUTO/MANUAL INDICATOR: Indicates A for Automatic or MAN for Manual controller mode. 8. DEVIATION  BARGRAPH:  Shows  deviation  between  Process  Variable  and  Set  Point.    Each  red  bar  indicates  a deviation of 1% of span (7 5 Degrees F for Type J TC L range) 9. [SET  UP]  KEY:  Places  the  controller  in  the  Set  Up  mode  Sequentially  displays  Set  Up  and  Calibration  groups  and enables the [FUNC] key to display individual functions within each Set Up group.  Selections made In this mode affect the basic operation of the Controller (deg C or deg.  F, Thermocouple type, Alarm type, etc ).  These codes have been preset by Hauck and should not be changed without consulting the Hauck service department. 10.  [FUNC]  KEY:  Used  In  conjunction  with  the  [SET  UP]  key  to  select  the  individual  functions  within  a  Set  Up  group Alternately selects between 2 local Set Points. 11.  [LOWR DISP] KEY: Selects the operating parameter shown in the Lower Display SP: Controller Set Point 2SP:  Second local Set Point when so configured DEV: Deviation between Process Temperature and Set Point OUT: Burner control motor position expressed as a percentage (0= Low Fire  100= High Fire). Also used to exit the SET UP mode and return the controller to its normal operating mode. (page 3-17)