Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: UDC3000 MICROPROCESSOR TEMPERATURE CONTROLLER
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
PANEL OPERATION-cont.
Up
TM-5-3895-374-24-1 Paving Machine Bituminous Material: Crawler Mounted Diesel Engine Driven Manual
Next
Fig 4-UDC3000 Temperature Controller

TM 5-3895-374-24-1 GP467FB 14.  Momentarily move the MAIN FLAME switch to the START position to ignite the main burner.  Main flame hold relay, R3, will be energized and latched on. AUTOMATIC FUEL VALVE APPLICATIONS a.  The main fuel and fuel blocking valves will OPEN and the gas vent or oil return valve as applicable will CLOSE. b.  Trial for ignition timer, 2TR, will begin its timed delay (10 seconds for gas or 15 seconds for oil). MANUAL RESET MAIN GAS VALVE APPLICATIONS a.  The main gas vent valve will CLOSE and the gas blocking valve will OPEN. b.  Manually operate the main gas valve lever to ignite the main burner and begin the 10 second trial for ignition 15.  After the trial for ignition period has been completed a.  The Ignition transformer and pilot solenoid valve will be de-energized. b.  The PILOT ON light will go OUT and the MAIN FLAME PROVED light will come ON. c.  Low fire hold timer, 3TR will begin its timed delay. NOTE If the main burner falls to ignite within the trial for ignition period the pilot and main fuel valves will CLOSE and  the  alarm  horn  will  sound  Silence  the  alarm  and  allow  the  system  to  repurge  before  attempting  to relight the pilot and main burner. 16.  After the low fire hold timer has completed its delay (5 seconds for gas or oil): a.  The burner control motor will respond to the output of the STACK TEMPERATURE controller. 17.  Start material feed to the dryer and press the [MAN/AUTO] key of the STACK TEMPERATURE controller to place the controller in the AUTOMATIC mode. 18.  After   the   MATERIAL   TEMPERATURE   controller   begins   to   respond   to   the   material   exiting   the   dryer   drum,   the CONTROL  MODE  selector  switch  may  be  moved  to  the  MATERIAL  position  and  the  MATERIAL  TEMPERATURE controller placed in the AUTOMATIC mode to transfer control of the burner motor to the material controller. 19.  To terminate burner operation move the  MAIN FLAME switch to the  OFF position and press the  ALARM SILENCE pushbutton. G.  UDC3000 MICROPROCESSOR TEMPERATURE CONTROLLER The UDC3000 Temperature Controllers have been preset at the factory with tuning parameters which generally produce accurate   temperature   control.      If   you   experience   temperature   control   problems,   PLEASE   CONTACT   THE   HAUCK SERVICE DEPARTMENT before adjusting the tuning parameters. Figure  4  shows  the  Operator  interface  of  the  UDC3000.    The  following  paragraphs  describe  the  function  of  the  various displays and keys.  Examples are given for changing the Controller Set Point, positioning the Burner Control Motor in the Manual Mode, and changing the High Stack Temperature alarm set point.  Additional information on the UDC3000 is given in the vendor literature. (page 3-16)

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing