Figure 2-11.—Expanding a tube.
Up
Utilitiesman Basic Volume 02 - Manual for electric, plumbing, water and other utilities
Next
Figure 2-14.—Removing plug from economizer element.

Tube  expanders  must  be  used  carefully  to  avoid damage  to  the  expanders  and  to  prevent  injury  to personnel. The centrifugal force developed by the air turbine is great, so the air motor must be gripped firmly with  both  hands.  If  the  roller-mandrel  combination should bind, the force of the air motor could break the mandrel  and  quite  possibly  cause  injury  to  the operator.  Always  have  a  person  stationed  nearby  to give immediate assistance if necessary. If you run into any trouble, your safety person may be able to crimp the  hose  quickly  and  thus  keep  the  mandrel  from breaking. BELLING  TUBES Most  tubes  are  expanded  and  belled.  However, Figure 2-12.—Belling tool. check  the  drawing  to  determine  if  any  specific instructions are shown. Some tubes in 1,200 psi boilers are  lightly  expanded  or  belled  before  welding;  some are directly butt-welded to the studs. A roller-type or a drift-type  belling  tool  is  used.  The  drift-type  tool  is shown in figure 2-12. When belling a tube, be careful not to overdo the operation. Tubes up to, but not including 2 inches OD should be belled at least 1-15 inch but no more than 1/8 inch. Tubes 2 inches OD and larger should be belled at least 1/8 inch, but no more than 3/16 inch. The increase is to be measured over the outside tube diameter at the end  of  the  tube.  Figure  2-13  shows  the  process  of belling a tube. Some  expanders  are  fitted  with  belling  rolls,  as shown in figure 2-9. When these expanders are used, the  tubes  are  expanded  and  belled  at  the  same  time; thus, there  is no need for a separate  belling job. RENEWING  WELDED  TUBES In  some  boilers  of  recent  design,  the  superheater tubes and the economizer tubes are welded after they have  been  expanded.  The  renewal  of  these  tubes  is more complicated than the renewal of ordinary tubes. Procedures  for  renewing  welding  tubes  are  given  in  the appropriate  manufacturer’s  technical  manual. PLUGGING  BOILER  TUBES CAUTION Any tube that is plugged must have a hole be replaced. drilled in it to prevent pressure buildup in the tube when the boiler is steamed. As  an  emergency  measure,  it  is  sometimes necessary to plug defective boiler tubes until they can Figure 2-13.—Belling a tube. Various  sizes  of  tube  plugs  are  carried  in  the supply  system.  The  plugs  are  tapered  to  the  required shape and are usually drilled and threaded at the larger end,  so  they  may  be  removed  with  a  tube  plug extractor. Tubes must be plugged at each end. Before driving a tube plug into position, be sure the plug and the inside of  the  tube  are  absolutely  clean,  so  the  plug  makes good  metal-to-metal  contact  with  the  tube.  Drive  the plug  far  enough  in  to  ensure  it  will  hold,  but  do  not drive it so far in that it damages the tube sheet. In plugging superheater tubes, use an offset driver to drive in the plugs when the tube holes do not fall in line  with  the  handhole  opening.  When  a  superheater tube  is  plugged,  it  will  eventually  burn  away  after  a period  of  service.  When  tubes  have  burned  away  (or when they have been removed) so much that they leave a gas lane more than three tube rows wide through the entire superheater tube bank, plug the gas lane with a 2-12