Procedure
Insert
The burner should ignite. When lit,
remove the preheater shield. Be sure that
you use a glove when handling the heater
shield.
Shut the preheater valve by turning it
fully clockwise. Now turn the flame
valve clockwise until the flame lowers to
the height of the generator. Adjust the air
shutter until the flame is green in color.
Place the flame valve knob back in the
holder.
Carry the burner unit to the cooking area
and place it in the cabinet.
Figure 2-10 shows the location and
describes the functionof the M-2 burner major
components.
Figure 2-11 shows the operating controls of the M-
2 burner.
CESSPOOLS, SEPTIC TANKS,
TILE FIELDS, AND LATRINES
Various facilities are used for treatment and
disposal of sewage at installations where common
sewers are not available.
2-16
|