Back Field Range Burner Unit | Up Utilitiesman Volume 01 - Manual for electric, plumbing, water and other utilities | Next Recommended Way of setting The Ffield Range Outfit |
The following inserts show the recommended way of setting up and operating the field range outfit.
Procedure
Insert
Take the burner unit to the fueling area at
least 50 feet away from the lighting and
cooking area. Place the burner in a vertical
position and release the air pressure by
turning the filler cap counterclockwise,
then remove the filler cap. Fill with 8 quarts
of mogas. Eight quarts will last
approximately 4 hours.
Take the burner unit 50 feet away from the
fueling area and the cooking area. Place the
unit in a horizontal position. Remove the
air valve cap, place a hand pump on the
valve, and pump until the pressure gauge
reads 6-8 pounds. Remove the pump and
replace the valve cap.
Turn the orifice cleaning control
completely around two or three times.
When completed, the handle should point
in the downward position.
2-14
|