Page Title: Figure 4-17.—Single-phase transformer connected to give 120/240-volt three-wire single-phase service.
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books

   

 

Back
Table  4-1.—Demand  Factor
Up
Construction Electrician Intermediate - Electricity handbook for electricians
Next
Figure 4-20.—Cluster-mounted bank of transformers.

Figure  4-17.—Single-phase  transformer  connected  to  give 120/240-volt  three-wire  single-phase  service.  Transformer secondary  coils  are  connected  in  series. ungrounded  delta  primary  voltage  system  to  obtain 120/240-volt   single-phase   three-wire   service. Normally the wire connected to the center low-voltage bushing will be connected to ground. Grounding the wire  connecting  to  the  center  bushing  limits  the voltage  aboveground  to  120  volts,  even  though  the wires  connecting  to  the  outside  secondary  bushings have 240 volts between them. Figure 4-18 schematically shows the single-phase distribution transformer connections to a three-phase four-wire wye grounded neutral primary system rated 4,160Y/2,400 volts to obtain 120/240-volt single- phase  secondary  service.  The  three-phase  four-wire wye grounded neutral system has voltage between phases equal to the phase or line to neutral voltage multiplied by 1.73. In figure 4-18, the primary system line to neutral voltage is 2,400 volts, and the voltage between phases is 1.73 times 2,400, or 4,160 volts. This  system  is  designated  as  a system. Other standard three-phase four-wire wye grounded   neutral   primary   system   voltages   are a n d The  transformer  connections  to  obtain  120, 120/240-volt  secondary  service  are  normally  completed inside the tank of the transformer (fig. 4-19). The Figure 4-19.—Shows connections for 120/240-volt three-wire, 240-volt  three-wire,  and  120-volt  two-wire  services. Figure 4-18.—Single-phase transformer connected to provide 120/240-volt three-wire single-phase service. Primary winding is connected to neutral or ground. 4-13