Operator’s Controls (Cont)
Up
TM-55-4920-413-13P System Analyzer Test Set Type 60B63-5A Manual
Next
CHAPTER 4 MAINTENANCE INSTRUCTIONS

TM  55-4920-413-13&P Table 3-1. Operator’s Controls (Cont) Control, indicator or connector ROTOR  SPEED NOR CAL HI  LO Variable  control LOW  ROTOR  SPD ROTOR  OVER  SPD  RESET  switch LAMP  SUPPLY  OVERLOAD  NO.  1 LAMP SUPPLY OVERLOAD NO. 2 LAMP SUPPLY OVERLOAD switch INPUT POWER Lamps: 115 VAC 28 VDC INPUT POWER switch LAMP TEST switch INTEGRAL  LIGHTING  switch 115 VAC 2A fuse 28 VDC  8A fuse 5 VAC 8A fuse Function Selects mode of operation - normal or calibration for check- ing % RPM R indicator. When ROTOR NOR CAL switch is set to CAL, HI LO switch allows high and low calibration points of % RPM R indicator to be checked. Used when NOR CAL switch is at NOR, to check operation of Rotor Speed indicator as simulated % RPM rotor speed signals cover  range  from  minimum  to  maximum. Indicates  operation  of  ROTOR  SPEED  LO  switch. Used to reset rotor overspeed warning indicator, Indicates  operation  of  LAMP  SUPPLY  OVERLOAD  switch. Used to select NO. 1 and NO. 2 lamp supply overload conditions. When lighted they indicate this: AC input power is applied. DC input power is applied, Three-position switch that controls application of 115 vac and 28 vdc power. At ON, input power is connected. At OFF, input power is disconnected, At SIM ONLY, input power to interconnect connector (J5) is removed. This removes  power  from  Unit  Tester,  de-energizing  it  without removing  power  from  SIMULATOR. NO. 2 Low Oil Pressures, NO. 1 and NO. 2 High Oil Tempera- ture, Low Rotor Speed, NO. 1 and NO. 2 Engine Out, and both Lamp  Supply  Overload  lamps  on  LTS. To select internal or external integral lighting power. AC power line fuse. Fuse blows if primary circuits of trans- formers T1, T2, T3, T4 become overloaded due to circuit malfunction. DC input power fuse, protects 28 vdc circuits. Protects 5 vac lighting circuits. 3-6

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing