TM  55-4920-410-13&P Section VI.  PREPARATION  FOR  SHIPMENT  AND  STORAGE 4-17.   General.   Preparation    for    shipment and/or  storage  depends  upon  whether  test  set  is retained  in  unit  area  evacuated.  Storage  in  unit area,  when  authorized,  is  on  a  rotational  basis and is known as Administrative Storage. 4-18.   Levels   of   [protection.   Select  the  level  of protection  which  best  suits  the  circumstances  and follow the instructions for that level. a. Level A. Use this level if shipment is into or out of a combat theater or is destined for outdoor storage or is destined for indoor storage exceeding five years. b. Level B. Use this level if the shipment involves over- seas surface transit and/or is destined for indoor storage up to five years. c. Level C. Use this level if shipment is entirely with- in CONUS and storage will not exceed two years. 4-19.    Procedures, a. For All Levels.  Clean the test set thoroughly of all contamination and debris. Use no cleaning fluids or preservative materials. Package each test set individual- ly. Each individual package can be shipped without pack- ing. Cushion the test set in 2 inches of one pound density polyethylene  foam  conforming  to  PPP-C-1752  and  include eight units of desiccant conforming to MIL-D-3464 with- in the unit. b. Unit Container. Provide a snug fitting unit contain- er as follows: (1) Level A. Wood-cleated, plywood conforming to style I, overseas type of PPP-B-601. (2) Level B. Weather-resistant fiberboard container conforming to PPP-B-636. (3) Level C. Domestic class fiberboard container con- forming  to  PPP-B-636. c. Marking. Mark all shipments in accordance with MIL-STD-129. Change   1   4-15

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing