Table 4-6. Point of Regulation TRIAC Isolation Procedure
Up
TM-55-4920-410-13P Vibrex Balancing Kit Part No. D4591 Manual
Next
Troubleshooting Table 4-7. Analyzer Test Set Circuits

CAUTION TM  55-4920-410-13&P (3) Set dc power supply to ON. (4) Set TRIP TIME START switch to off (down). Oscilloscope will indicate between 20 and 30 V p-p. If fre- quency counter does not indicate between 1145 and 1165 Hz, adjust R101 for 1155 Hz. If specification cannot be met go to troubleshooting Table 4-7. (5) Set TRIP TIME START switch to ON (up). Os- cilloscope will indicate between 20 and 30 V p-p. If fre- quency counter does not indicate between 1085 and 1105 Hz, adjust R102, for 1095 Hz. If specification cannot be met go to troubleshooting Table 4-7. m. Timer  Time  Delay  Circuit. (1) Set dc power supply to OFF and disconnect all equipment  from  equipment  setup  except  dc  power  supply. (2)  Connect  frequency  counter  and  oscilloscope  to channel A to J2 TRIG and channel B to J4 T2 CAL, using two probes and two adapters (B12 and B13). Set oscillo- scope trigger controls to starts weep when waveform goes from O to +20 vale. (a) (c) Adjust frequency counter to accept at least a 56 V pulse before proceeding to next step. (3) Set dc power supply switch to ON. (4) Position frequency counter controls as listed in through  (g)  below: (a) (b) (c) (d) (e) (f) (g) Slope channels to +. Function to BA. Trigger levels (Slightly +). Display fully CW. Press   RESET. SEP-COM to SEP. Gate time switch to min. (5) Position Test set controls as listed in (a) through below: (a) TRIP TIME START switch to off (down). (b) TEST SELECT switch to 3Ø OVB. 4-10 (c) TRIP TIME START switch to on (up). TEST IN PROCESS light goes on. (6)  Press  frequency  counter  RESET  pushbutton.  If frequency counter does not indicate between 100 and 140 ms, adjust R1 (Figure 4-6) for 120 ms. If specification can- not be met, go to troubleshooting Table 4-7 (Fault No. 2). (7)   Set   frequency   counter   to   indicate   seconds and  press  RESET  pushbutton. (8) Disconnect hookup from J4 T2 CAL and recon- nect to J3 T1 CAL. (9) Position Test set controls as listed in (a) through (c)  below: (a) TRIP TIME START switch to off (down). (b) TEST SELECT to AØ UV. (c) TRIP TIME START switch to on (up). (10) If frequency counter does not indicate between 3.0 and 4.0s, adjust R5 for 3.5S. If specification cannot be met, go to troubleshooting Table 4-7 (Fault No. 3). (11)  Disconnect  hookup  from  J3  to  T1  CAL  and reconnect to J4 T2 CAL. (12) Set TRIP TIME START switch to off (down), then to on (up). If frequency counter does not indicate be- tween 4.5 and 5.5s, adjust R3 for 5S. If specification can- not be met, go to troubleshooting Table 4-7 (Fault No. 4). (13) Disconnect hookup from J4 T2 CAL and recon- nect to J3 T1 CAL. (14)  Position  Test  set  controls  as  listed  in  (a)  through (c)  below: (a) TRIP TIME START switch to off (down). (b)  TEST  SELECT  switch  to  UND  FREQ. (c) TRIP TIME START switch to on (up). (15) If frequency counter does not indicate between 900 and 1100 ms, adjust R119 for 1000 ms. If specification cannot be met, go to troubleshooting Table 4-7 (Fault No. 5). (16)  Disconnect  hookup  from  J3  to  T1  CAL  and reconnect to J4 T2 CAL. (17) Set TRIP TIME START switch to off (down), then to on (up). If frequency counter does not indicate be-

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing