Page Title: Table 4-6. Point of Regulation TRIAC Isolation Procedure
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Table 4-5. Panel Point of Regulation
Up
TM-55-4920-410-13P Vibrex Balancing Kit Part No. D4591 Manual
Next
m. Timer  Time  Delay  Circuit.

(3) Set CT CURRENT READ switch to OFF and TEST SELECT to AØ DC CT position. (4) Connect 28 vdc power supply to J1 pins S(-) and J (+) and push 400 Hz circuit breaker to IN. (5) Set current limit 30 KVA/20 KVA to 20 KVA. Digital   VOM   will   indicate   24   ohms.   If   not,   see troubleshooting  Table  4-7. (6) Set current limit 30 KVA/20 KVA to 30 KVA. Digital   VOM   will   indicate   14   ohms.   If   not,   see troubleshooting  Table  4-7. (7) Set current limit 30 KVA/20 KVA to OFF and set FF GO/NO GO to NO GO. Digital VOM will indicate 2K ohms. If not, see troubleshooting Table 4-7. (8) Set FF switch to GO. Digital VOM will indicate 4K ohms. If not, see troubleshooting Table 4-7. (9) Disconnect all test equipment from test set and set all test switches to down or OFF. k. Regulation  TRIAC  Isolation  Procedure. (1)  Pull  400  GEN  TI  circuit  breaker  to  OUT position. TM 55-4920-410-13&P (2)  Remove  circuit  board  assembly  A2  and  reinstall using extender board. (3)  Connect  equipment  as  shown  in  Figure  4-2  (DC power  supply  not  connected). (4)   Push   400   GEN   TI   circuit   breaker   to   IN position. (5)  Perform  voltage  checks  Table  4-6using  TEST SELECT switch at positions and test points specified. Indications will be as specified. If not, see troubleshoot- ing  Table  4-7. (6) Disconnect all test equipment from test set and set test switches to the down or OFF position. 1. Underfrequency Circuit. (1) Set dc power supply to OFF and disconnect fre- quency counter from equipment setup. (2)  Connect  frequency  counter  and  oscilloscope  to J5 UFCAL, using adapters, cables, and X10 probes. NOTE Connect probes to frequency counter INPUT. Table 4-6. Point of Regulation TRIAC Isolation Procedure 4-9

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing