TM 55-4920-410-13&P 4-11. Troubleshooting and Repair (ATST). a. Paras 4-11 and 4-12 contain general information for troubleshooting.  Test  equipment  and  accessories  are listed in Tables 4-3 and 4-4. Refer to FO-1 for the test set schematic diagram and Fig C-3 for the electrical compo- nent  assembly.  Troubleshooting  procedures  are  listed  in tables 4-7 and 4-8. The adapter cable wiring diagram is Fig 4-7.  See  troubleshooting  tables  as  applicable  before proceeding  with  performance  checks. b.  Extender  board,  Bendix,  P/N  1106610-1  is  required for troubleshooting circuit boards and is listed in table 4-4. 4-12. Analyzer  Circuit  Checks. a.  GEN/PMG   VOLTS   Meter. (1) Set all test switches to down or OFF. (2) Set GEN/PMG VOLTS switches to T1. (3) Pull 400 GEN-T1, T2, and T3 circuit breakers to out position. (4) Connect test equipment as shown in Figure 4-2 (DC power  supply  not  connected). (5) Set AC power supply to ON and adjust for l15V output   at   400   Hz. (6) Push 400 GEN-T1 circuit breaker to IN posi- tion. Observe test set for a 115V indication on GEN/PMG Volts meter. If not, see troubleshooting Table 4-7. (7’) Pull 400 GEN-T1 circuit breaker to OUT posi- tion and disconnect lead from pin A of J1 and connect to pin B of J1. (8) Set GEN/PMG VOLTS switch to T2 and repeat (3) thru (7) above, except use 400  GEN-T2  circuit  breaker. (9) Disconnect lead from pin B of J1 and connect to pin C of J1. (10) Set GEN/PMG VOLTS switch to T3 and repeat (3) thru (6) above, except use 400 GEN-T3 circuit breaker. (11) Disconnect test equiment from test set. b. FREQUENCY  METER  Circuit. (1) Connect test equipment as shown in Figure 4-2 (DC power supply not connected) with  test set power OFF. (2) Set all test switches to down or OFF. (3) Set GEN/PMG VOLTS switches to T1. (4)  Pull  400  GEN-T1  circuit  breaker  to position. OUT (5)  Press  400  GEN-T1  circuit  breaker  to  IN position. 4-4 (6) Adjust AC power supply for 400 Hz indication on FREQUENCY METER. If not, see troubleshooting Table  4-7. (7) Disconnect test equipment from test set. c. PMG  Volts  Meter  and  1200  Hz  Power  Circuit. (1) Pull PMG AØ, BØ, and CØ circuit breakers to OUT positions and set GEN/PMG VOLTS switch to AB. (2) Connect equipment as shown in Figure 4-3 and set all test switches to down or OFF. (3) Adjust AC power supply for 21 vac at 1200 HZ and push PMG AØ and BØ circuit breakers to  IN posi- sitions. (4) GEN/PMG Volts meter will indicate approxi- mately 21 vat. If not, see troubleshooting Table 4-7. (5) Pull PMG AØ and BØ circuit breakers to OUT positions. (6) Connect test lead to J1 connector pin X (+) and w (–) to the digital voltmeter. (7) Push PMG AØ and BØ circuit breakers to IN positions. (8) Digital voltmeter will indicate approximately 27.5 vdc. If not, perform troubleshooting Table 4-7. (9) Pull PMG AØ and BØ circuit breakers to OUT positions. (10) Disconnect lead from pin D of J1 and connect to pin F of J1 and set GEN/PMG VOLTS switch to BC and push PMG BØ and CØ circuit breakers to IN positions. (11)  Repeat  technique  (8)  above. (12) Pull PMG BØ and CØ circuit breakers to OUT positions. (13) Disconnect lead from pin E of J1 and connect to pin D of J1. (14) Set GEN/PMG VOLTS switch to CA and push PMG CØ and AØ circuit breakers to IN positions. (15)  Repeat  technique  (8)  above. (16) Disconnect test equipment from test set and set all test switches to down or OFF. d.  400   Hz   Power   Supply   Circuit. (1) Pull 400 Hz GEN T-1 circuit breaker to OUT position  and  set  GEN/PMG  VOLTS  switch  to  T1.  Observe that all other test switches are down or OFF. (2) Connect test quipment as shown in Figure 4-2 (DC power  supply  not  connected)  with  digital  voltmeter leads between J1 connector pins X (+) and w (–).

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing