CHAPTER   4 MAINTENANCE    INSTRUCTIONS
Up
TM-55-4920-410-13P Vibrex Balancing Kit Part No. D4591 Manual
Next
SectIon Ill. REPAINTING AND REFINISHING INSTRUCTIONS

TM   55-4920-410-13&P Section Il. TROUBLESHOOTING 4-3.   Scope. b. This manual  cannot  list  all  possible  malfunctions  that may occur or all tests or inspections and corrective ac- tions.  If  a  malfunction  is  not  listed  (except  when  malfunc- a. This section contains troubleshooting or malfunction tion and cause are obvious), or is not corrected by listed information and tests for locating and correcting most of corrective  actions,  you  should  notify  higher  level  main- the troubles which may develop in the Test Set. Each mal- tenance. function  or  trouble  symptom  for  an  individual  component, c. Table 4-2 lists the common malfunctions that you may unit, or system is followed by a list of tests or inspections find during the operation or maintenance of the Test Set necessary for you to determine probable causes and cor- or  its  components.  You  should  do  the  tests/inspections  and rective  actions  for  you  to  remedy  the  malfunction. corrective  actions  in  the  order  listed. - Table 4-2. Troubleshooting (AVUM) MALFUNCTION TEST  OR  INSPECTION CORRECTIVE   ACTION 1. AN  INDIVIDUAL  PRESS-TO-TEST  INDICATOR  DOES  NOT  GO  ON  WITH  THE EXCEPTION OF  Ø SEQ  T1-2-3. Step  1.  Start  APU. Step 2. Press each press-to-test indicator except Ø SEQ T1-2-3. Indicators shall light when pressed, a. If only one indicator does not light, replace lamp, paragraph 4-7. b. If all lamps do not light, send test set to higher maintenance. 2. TEST SET Ø SEQ T 1-2-3 INDICATOR DOES NOT GO ON. Step 1. Place GEN switch OFF then ON while holding TEST SET switch at RESET. Test set Ø SEQ T1-2-3 indicator shall go on. a. If indicator does not go on, press Ø SEQ T1-2-3 press-to-test. If lamp does not light, replace  lamp,  paragraph  4-7. b. If lamp goes on when press-to-test is pressed, send test set to higher maintenance. 4-2

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing