DATA INPUT LEVEL OPTIONS
INPUT VOLTAGE RANGES
Input Data
"1" or Mark
"O" or Space
Zero Reference
-10 to -0.5v
+0.5 to10v
+10 to +0.5v
-0.5 to -10v
Positive Offset
-10 to +1v
+2.2 to 10v
+10 to +2.2v
+1 to 10v
Negative Offset
-10 to -2.2v
-1 to 10v
+10 to -1v
-2.2 to -10v
NOTES:
1. Positive and negative operating points for zero reference option are balanced within 10%.
2. Additional Strapping options will accept input voltages up to twice those listed above.