CHAPTER 4 ORGANIZATIONAL MAINTENANCE
Up
TM-11-7025-229-12 Disk Memory Unit MU-768/G (NSN 7025-01-155-0172) Manual
Next
Table 4-1. Disk Unit Malfunction/Symptom Index

TM11-7025-229-12
Section II. TROUBLESHOOTING
4-6.
INTRODUCTION
The disk unit is a complex piece of electronic equipment. Organizational maintenance personnel perform only those
troubleshooting procedures contained within this manual. If a malfunction occurs that is not covered in this manual, or if
the listed maintenance action does not correct the trouble, the disk unit is removed from its mounting and replaced with a
functioning spare disk unit. The defective disk unit is then referred to higher levels of maintenance for repair.
NOTE
This manual cannot list all malfunctions that might occur, or all tests, inspections, and
corrective actions required. If a malfunction is not listed, or is not resolved by the listed
corrective actions, notify the shift supervisor.
4-7.
USE OF TROUBLESHOOTING FLOWCHARTS
a.
Locate the malfunction in the Symptom Index.
b.
Note that the troubleshooting flowcharts and procedures are indexed by malfunction/symptom.
c.
Review the sample flowchart (fig. 4-1) to become familiar with the proper use of troubleshooting flowcharts.
4-8.
SYMPTOM INDEX
Table 4-1 provides an index of probable equipment malfunction symptoms. Use the index to quickly locate applicable
troubleshooting flowchart and/or procedures to determine the required corrective action(s).
CAUTIONS
DO NOT remove the HDA or cabling with the unit's power on. Position PWR ON/PWR
OFF switch to PWR OFF first.
Always handle the disk unit with extreme care, especially the HDA. Improper handling
of the unit can cause head crashes.
4-2