OPERATOR'S MAINTENANCE
3-1.
GENERAL
This chapter provides the operator's maintenance instructions and procedures for the Disk Memory Unit MU-768/G.
Operator maintenance is limited to cleaning and replacing air filters.
3-2.
LUBRICATION
No lubrication or lubricants required.
3-3.
CLEANING
The following cleaning procedure is to be performed by the operator as required.
a.
Remove dust and dirt from exterior surfaces using a clean, lint-free cloth (item 3, appx E).
WARNING
Isopropyl alcohol is extremely flammable; use is well ventilated area away from fire,
sparks, or any other heat source. When not in use, keep alcohol container closed.
b.
Remove grease using a clean, lint-free cloth (item 3, appx E) soaked with isopropyl alcohol. Wipe dry
using a clean, lint-free cloth.
c.
Use a bristle brush (item 2, appx E) to remove dirt from hard to reach areas.
NOTE
ELAPSED TIME indicator can be checked by observing the movement of the flag
between the first and second digits.
d.
Verify that the ELAPSED TIME indicator appears to be operating.