![]() ![]() SAFETY PRECAUTIONS
LISTED BELOW IS EVERY "WARNING" CONTAINED IN THIS MANUAL,
ALL PERSONNEL IN-
VOLVED IN THE OPERATION AND MAINTENANCE OF THIS EQUIPMENT MUST
FULLY UNDERSTAND THE 'WARNING" AND THE PROCEDURE BY WHICH
THE HAZARD IS TO BE REDUCED OR ELIMINATED. PERSONNEL SHALL
BECOME THOROUGHLY FAMILIAR WITHALL ASPECTS OF SAFETY OF PER-
SONNEL AND EQUIPMENT PRIOR TO THE OPERATION AND MAINTENANCE
OF THE EQUIPMENT.
1. Operate the compressor package assembly only in well-ventilated areas or with the engine exhaust gases vented
outdoors. Engine exhaust gas contains lethal carbon monoxide which is colorless and odorless. When inhaled,
carbon monoxide will cause serious, and sometimes fatal, illness. If the exhaust gases enter the compressor
intake, the air storage bottles being charged will be contaminated and the air unfit for breathing.
2. High-pressure air can cause serious injury to operating personnel. Always make certain the connecting tube
assemblies, hoses and other component parts of the compressor package assembly are in good condition. In
particular, never use an air hose assembly or filler attachments that are damaged or appear in questionable
condition.
3. Never charge an air storage bottle or other pneumatic equipment with compressed air if the proof pressure or
rating of the equipment is unknown. Never charge equipment to a pressure in excess of its known rating.
4. Severe explosion will result if a container partially filled with oxygen is charged with air. If any doubt exists as to
the contents of a container, thoroughly vent the container and flush with water or air at zero pressure before
charging.
5. The pressure relief valve assemblies are preadjusted to open and relieve system air pressure when the pressure
exceeds a safe value. Operating personnel should never attempt to change the setting of the pressure relief
valve assemblies.
6. When compressing breathing quality air, use only special medicinal grade, mineral base lubricating oil for
compressor lubrication.
7. Always stop the gasoline engine before attempting to fill the fuel tank, and exercise extreme care to avoid spilling
gasoline on a hot engine.
8. When operating the compressor package assembly at ambient temperatures below 40° Fahrenheit, connect a
source of 27-volt direct current to the electrical connector on the instrument panel.
9. The oil-water -air emulsion which blows down when the push valve is pressed can cause painful injuries. Be
extremely careful to stay clear of the blow down tube directly beneath the filter and separator assembly.
10. Be sure receiver shutoff valve is closed and system drain valve open before attempting to remove the line filter