HINGED PLATE REMOVAL PROCEDURE
Up
TM-9-2350-222-20-2-3-2 Turret for Combat Engineer Vehicle M728 (2350-00-795-1797) Manual
Next
Schematic Drawing

TM 9-2350-222-20-2-3-2
HINGED PLATE REMOVAL PROCEDURE (CONT)
19-8.
FRAME 1
Procedure
Step
1.
Traverse turret until periscope stowage box (1) can be reached from driver's compartment
(TM-10)
Set turret traverse lock to LOCKED (TM-10).
2.
Open two latches (2) and open door (3).
3.
Open door (4) to provide access to nuts (5).
4.
NOTE
Flat washers (6) under hinged plate (7) are used as
shims to keep rubber pad of hinged plate against
periscope head. The number of flat washers must be
marked with pencil on periscope stowage box (1) near
all four flat washer locations to help put them back
( para 19-9 ). Also, use pencil to mark top of hinged plate
near top holes so it can be put back in same position
Using screwdriver and wrench, remove two screws ( 8), two lockwashers (9), two nuts (5)
5.
and flat washers (6) that attach hinged plate (7) to door (4).
Open two latches (10) and open door (11).
6.
Using screwdriver and wrench. remove two screws ( 8), two lockwashers ( 9). two nuts (5)
7.
and flat washers (8) that hold hinged plate (7) on periscope stowage box (1). Remove
hinged plate.
Close doors (4), (3), and (11).
8.
END OF TASK