3-4.
SYNCHRONIZATION AND BACKLASH CHECK OF 165 MM GUN WITH
GUNNER'S PERISCOPE M32C-RAMP METHOD (CONT)
Procedure
While looking through daylight eyepiece of gunner's periscope, adjust boresight knobs (1)
1.
and (2) to line up aiming cross of reticle on same aiming point as gun (view A).
2.
Turn slip scales of boresight knobs (1) and (2) to setting of 4.
While looking through telescope eyepiece, adjust elevation and deflection boresight knobs
3.
(3) and (4) until aiming cross of reticle is on same aiming point as gun (view A).
4.
Turn slip scale of boresight knobs (3) and (4) to settings of 3.
NOTE
At this point a boresight reference has been set up
between the gun and periscope.