![]() ![]() TM 9-2350-222-20-2-1
WAR TIME PREVENTIVE MAINTENANCE
2-10.
CBR System
PERSONNEL: One
TM 9-2350-222-20-2-3 for procedure to remove/install GPFU Filters
REFERENCE:
Reference
Procedure
Step
Item to be Inspected
U n i t commander or senior officer in charge of
maintenance personnel who are assigned to remove and
dispose of contaminated gas filters must prescribe
necessary protective clothing to be worn (TM 10-277).
U n i t commander or senior officer i n c h a r g e o f
maintenance personnel who are assigned to remove and
dispose of contaminated gas filters must prescribe
n e c e s s a r y safety measures that must be followed
including decontamination operation before new gas
filters are installed (TM 3-220 ).
Hull Maintenance
Redate all filters:
GPFU Filters (one
1.
a. W h e n use of AC (Hydrogen
M19 particulate filter
Cyanide) or CK (Cyanogen
and two M18 filters)
Chloride) is expected.
At the beginning of combat
b.
conditions.
After 1,500 hours of
c.
operation in wartime
conditions with chemical
agents used
After each AC (Hydrogen
d.
Cyanide) or CK (Cyanogen
Chloride) attack.
After 10,000 hours of
e.
operation in war time
conditions with no chemical
agents used.
END OF TASK
Para 2-10
2-22
|
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |