TM 9-2350-222-20-1-5
SMOKE GENERATOR WIRING HARNESS TO BULKHEAD LEAD REPLACEMENT
(Sheet 2 of 2)
4.
Using spanner wrench, connect and tighten
cable connector (D) to bulkhead connector.
5.
Connect connectors (E) and (F).
6.
Connect battery ground straps (page 10-283).
WARNING
Never activate smoke generator in a building or closed area or
with personnel near.
7.
Start engine (TM 9-2350-222-10) and run until normal operating temperatures are attained. Run
engine at 1600 rpm and set SMOKE GENERATOR switch ON for 10 seconds. Have one person
look for white smoke emitting from exhaust, turn SMOKE GENERATOR switch OFF, shut down
engine. If white smoke was not seen, troubleshoot (page 4-963).
End of Task
TA140863
23-11