TM 9-2350-222-20-1-4
INSPECTION AND REPAIR OFCOUPLING STOP
NOTE
Ring assembly is made up of lock ring
and clasp ring.
1. Install screw (A) in ring assembly (B) and
finger tighten.
NOTE
Metal to metal contact is preferred for a
serviceable ring.
2.
Check clearance of stop (C). If clearance is
.005 in. or less, ring assembly(B) is service-
able. If clearance is greater than .005 inch,
remove screw from (A) from ring assembly
(B) and continue to step 3.
Braze a bead across top of stop (C) surface.
3.
NOTE
Metal to metal contact should exist across
most of the length of the brazed bead.
4. File brazed bead down until metal to metal
contact exists between stop (C) and lock ring
(D).
Change 4 12-8.5