TM 9-2360-222-20-14
SHIFTING CONTROL AND RELATED PARTS REPAIR AND REPLACEMENT
(Sheet 8 of 15)
21. Using hammer and 1/8 inch punch, remove pin (AG).
22. Using 9/16 inch wrench, remove rod ends (AH) and
23. If stud (AK) is to be replaced, thread stud (AK) into rod end until 31/32 inch of stud (AK) can be
measured outside of rod end.
24. Using drill and vise, drill a 1/8 inch hole
through rod end and stud, 1/2 inch from bolt
5
L
end of rod.
25. Using hammer and punch, install new pin (AG)
in drilled hole.
26. Using 9/16 inch wrench, install new rod end on
other end of stud.
Go on to Sheet 9
TA139285
11-32