5.
Aline control panel (A) between mounting
bracket (F).
NOTE
Support panel in mounting
l o c a t i o n while installing screws
(G).
6.
Install two screws and new lockwashers (G) on
left side of control panel (A) securing panel to
bracket (F).
7. Install two screws and new lockwashers (G)
on right side of control panel (A) securing
panel and generator switch assembly (H) (if
so equipped) to bracket (F).
8. Using combination wrench, tighten two
screws (G) on left side of control panel.
9. Using socket, extension, and ratchet, tighten
two screws (G) on right side of control panel
(A).
10. Using spanner wrench install cable
connector: (J), (K), (L), and (M).
11. Connect three battery ground cables
12. Perform functional test (TM 9-2350-222-10).