MASTER CONTROL PANEL REPLACEMENT (Sheet 2 of 4)
2.
Using 7/16 inch wrench, remove two screws
and lockwashers (F) securing left side of master
control panel (E) to bracket (G). Throw
lockwashers away.
NOTE
Support master control panel
while removing r e m a i n i n g two
screws.
NOTE
vehicles
which
Only
are
equipped for deep water fording
have
the
generator switch
assembly.
Using socket, remove
two screws and lockwashers (F) securing
right side of master control panel (E) and
generator switch assembly (H) (if so
equipped) to bracket (G). Throw lockwashers
away.
4.
Lower master control panel (E) away from
brackets (G) to gain access to back of panel.
5.
Using spanner wrench, disconnect connector (J)
from back of master control panel (E).
Go on to Sheet 3
10-49
|
|