![]() ![]() TM 9-2350-222-20-1-4
MASTER CONTROL PANEL DISPLACEMENT (Sheet 2 of 3)
REMOVAL:
Set MASTER BATTERY switch to OFF.
1.
NOTE
S u p p o r t master control panel
while performing the following
steps.
NOTE
Only late model tanks will have
the air cleaner blower motor
If switch.
s w i t c h bracket.
bracket is not present, perform
step two to remove screws (A)
only.
Using wrenches, remove two screws and lockwashers (A) securing air cleaner blower switch
2.
bracket (B) on right side of master control panel (C). Throw lockwashers away.
Position air cleaner blower switch bracket (B) aside.
3.
4.
Using wrenches, remove two screws and
lockwashers (D) securing left side of master
control panel (C). Throw lockwashers away.
Lower master control panel (C) to gain access to
5.
rear of panel.
Go on to Sheet 3
TA139602
10-46
|
|