CLUSTER ASSEMBLY MOUNTING BRACKET REPLACEMENT (Sheet 1 of 1)
TOOLS: 5/16 in. combination box and open end wrench
Cross-tip screwdriver
SUPPLIES: Lockwashers (MS35338-42) (8 required)
PRELIMINARY PROCEDURE: Remove instrument panel
cluster assembly (10-1 23)
REMOVAL:
1.
Using wrench and screwdriver, remove eight screws (A), lockwashers (B), and nuts (C) securing
four brackets (D) to panel (E). Throw lockwashers away.
Remove four brackets (D).
2.
INSTALLATION:
Place brackets (D) in position on panel (E).
1.
2.
Using wrench and screwdriver, install eight screws (A), new lockwashers (B), and nuts (C).
3.
Install cluster assembly (page 10-125).
4.
Make sure cluster assembly is secure in panel support.
End of Task