TM 10-3510-226-23
0067 00
REPLACE-CONTINUED
Replace the Fan Motor
WARNING
Ensure that all dryer electrical power is shut off and disconnected before proceeding.
The circuit breaker box or individual circuit breaker should be locked and tagged out by
personnel following this procedure. Remember that the CBL is a wet environment.
Serious injury or death to personnel can result from electrocution if proper safety
precautions are not observed.
WARNING
Ensure that the dryer power is shut off and disconnected before proceeding. Rotating
machinery and belts may snag fingers, hair, or clothing. Failure to observe safety
precautions may result in serious injury or death to personnel.
1. Disconnect power.
2. Remove the belts IAW procedures given in WP 0066 00.
3. Remove screws retaining motor junction box cover (Figure 4, Item 8), and remove cover.
4. Tag and disconnect wiring from motor (Figure 4, Item 9).
5. Remove the conduit (Figure 4, Item 10) with wiring from the motor.
10
9
8
Figure 4. Replace the Fan Motor.
0067 00-7