TM 10-3510-226-23
0037 00
REPLACE-CONTINUED
12. Install replacement pump assembly (Figure 5, Item 21) to pump upper mount, and retain with
screws, washers, and nuts.
13. Remove screws retaining end cover (Figure 5, Item 1) on replacement pump motor (Figure 5, Item
4), and remove end cover.
14. Knock out conduit plug if necessary.
15. Install conduit (Figure 5, Item 13) to motor (Figure 5, Item 14), and retain with locknut.
16. Connect conduit wiring to motor leads (Figure 5, Item 2) as tagged.
17. Install pump end cover (Figure 5, Item 1), and retain with screws.
18. Install pump (Figure 5, Item 21) with upper mount (Figure 5, Item 19) as an assembly to pump lower
mount (Figure 5, Item 20) and retain with screws, washers, rubber isolation washers, and nuts.
19. Install pump suction fittings (Figure 6, Item 18) as an assembly, and ensure alignment is correct.
20. Install pump discharge fittings (Figure 5, Item 17) as an assembly, and ensure alignment is correct.
21. Install pump suction hose (Figure 5, Item 16), and retain with clamp.
22. Install pump discharge hose (Figure 5, Item 15), and retain with clamp.
23. Reinstall heat trace and pump insulation (Figure 5, Item 14).
24. Operate pump IAW procedures given in TM 10-3510-226-10, and monitor for normal operation.
0037 00-11