TM  55-1520-240-23-9 11-7 INSPECT  FLIGHT CONTROL SYSTEM  ALUMINUM  AND  STEEL CONNECTING LINKS (Continued) 11-7 Do  not  reuse  rod  ends  removed from  fixed  end  of  connecting  links. Adjustable  rod  ends cannot have  a hole  in  them.   Rod  end  could  fail, resulting  in  loss  of  flight  control. 11. Check link for  loose  swaged  inserts as follows: NOTE Loose  swaged  inserts  occur  more above  mixing  linkage  control stops. a. Remove  hydraulic  power. b. Check  links between  sta.  444  and  482  first. c. Check  ends  of  link for  black  dust.   If dust is found,  insert  is loose. d. Check  end  of  link  for  position  of  insert. Position  of insert  must be  flush  to  0.031 inch out  of  tube.  If not within  limits,  insert  is loose. e. Apply  hydraulic  pressure  and  check  for movement of  loose  insert. f. Remove  hydraulic  power. g. Move  link  by hand.  If  insert  moves, replace link. h. If  insert  does  not  move  under  hand  load,  but insert  is not  flush  with  tube  or  is  out of tube more  than  0.031 inch,  replace  link. i. If  black  dust  is  found  at  insert,  remove  link for  repair. j. If  insert  is  loose  when  moved  by  hand, replace  link. FOLLOW-ON  MAINTENANCE: As  Required END  OF  TASK 11-38