TM  55-1520-240-23-9 11-6.3 ISOLATION  PROCEDURES FOR CHECKING CONTROLS LOOSENESS (Continued) 11-6.3 CHECK  FIRST STAGE BELLCRANKS 45.1. Position  dial indicator  (35) against  yaw  bellcrank (51.1).   Move  yaw  bellcrank axially  along  shaft (51.2).  Total axial  movement  shall  not be  more than  0.063  inch. 45.2. Remove  indicator  (35). 45.3. Position  dial  indicator  (35)  against  thrust bellcrank  (51.3).   Move  thrust  bellcrank axially along  shaft  (51.2).   Total  axial  movement  shall not  exceed  0.063 inch. 45.4. Remove  dial  indicator  (35). 11-32