TM  55-1520-240-23-9 11-6.3 ISOLATION  PROCEDURES FOR CHECKING CONTROLS LOOSENESS (Continued) 11-6.3 19. Position  indicator (33) against  rod  end  bearing (36).  Set indicator  at  mid-stroke. 20. Attach  scale  (35) to  bellcrank  (29).   Use  twine (E433). 21. Repeat  steps  15,  16,  17,  and  18. 22. Remove  indicator (33) and  support  (31). 23. Remove  nut (23),  two  washers (24  and  25), and bolt  (26)  from  link  (28). 24. Position  link  (28)  on  bellcrank  (27).  Install  bolt (26), two  washers (25  and  24),  and  nut (23). 25. Torque  nut  (23) to  30 to 40  inch-pounds.  Install cotter  pin  (22). 26. Repeat  steps  23  and  24  for  link  (30)  and bellcrank  (29). 27. Check  two  bolts  (26  and  37).   Bolts  shall  not rotate  with  torque  less  than  10 inch-pounds. There  shall  be  no  axial looseness.  If bolt  rotates or is  loose, add  washer  under  nut,  and  repeat step  25. 28. Working  from  cabin,  remove  cotter pin  (38),  nut (39), two  washers (40  and  41),  and  bolt  (42) from bellcrank (43).   Disconnect connecting  link  (44) from  bellcrank. 29. Install  bolt  (42),  two  washers (40  and  41),  and nut  (39) loosely  in  link (44). 30. Repeat  steps  28  and  29  for bellcrank  (45) and connecting  link  (46). 11-30