TM  55-1520-240-23-9 11-6.3 ISOLATION PROCEDURES FOR CHECKING CONTROLS LOOSENESS (Continued) 11-6.3 GENERAL CHECKS 4. Check  for missing  cotter pins  (18). 5. Check  for  loose  nuts (19) and  bolts (20). 6. Check  for  loose  rod  end  bearing  nuts  (21). CHECK  INTERMEDIATE  AND  FIRST  STAGE CONNECTING  LINKS 7. Remove  closet  acoustic  blanket  (Task 2-107). 8. Remove  closet  backup  panel  (Task  2-2). 9. Remove  forward  transmission  drip  pan  (Task 2-3). 10. Working  from  passageway,  remove  cotter  pin (22),  nut  (23),  two  washers  (24  and  25), and  bolt (26) from bellcrank  (27).  Disconnect connecting link  (28) from  bellcrank. 11. Install  bolt  (26), two  washers  (24  and  25),  and nut  (23)  loosely  in  link  (28). 12. Repeat steps 10  and  11  for  bellcrank  (29)  and connecting  link  (30). 13. Mount  support  (31) on  structure  (32).   Position dial  indicator (33) against  rod  end  bearing  (34). Set indicator  at  mid-stroke. 14. Attach  dial indicating  scale  (35) to  bellcrank (27). Use  twine  (E433). 15. Have  helper  pull  scale  (35)  up  until  scale indicates  10 pounds.   Record  indicator  (33) reading  as ‘A’. 16. Pull  scale  (35) down  until  scale  indicates  10 pounds.  Record  indicator (33)  reading  as  ‘B’. 17. Subtract reading  ‘B’ from reading  ‘A’.  Result shall not  be  more  than  0.063 inch.  If  more,  perform Tasks  11-7  and  11-9. 18. Remove  scale  (35) from  bellcrank  (27). 11-29