TM  55-1520-240-23-9 11-6.2 CHECK CONTROLS  FOR  OVERALL LOOSENESS (Continued) 11-6.2 1. Working  from  forward  left work platform,  attach scale  (1)  to  bolt (2)  of forward  left bellcrank (3). 2. Have  helper  pull  scale  (1)  down  until  scale indicates  10  pounds.   Measure  distance  ‘A’ between  bolt  (2)  and  top  surface  (4)  of  fitting  (5). 3. Have  helper  pull  scale  (1)  up  until scale  indicates 10 pounds.  Measure  distance  ‘B’  between  bolt (2)  and  surface  (4). 4. Subtract  distance  ‘A’  from  distance  ‘B’.  Result shall  not  be  more  than  0.375  inch.   If  more, perform  Tasks  11-7,  11-7.1,  and  11-9,  then 11-6.3. 5. Remove  scale  (1)  from  bolts  (2). 6. Working  from  forward  right  work  platform,  attach scale  (1)  to  bolt (6)  of forward  right  bellcrank  (7). 7. Have  helper  pull  scale  (1)  down  until  scale indicates  10 pounds.   Measure  distance  ‘C’ between  bolt  (6)  and  forward  surface  (8)  at  sta. 120.00. 8. Have  helper  pull  scale  (1)  up  until scale  indicates 10 pounds.  Measure  distance  ‘D’  between  bolt (6)  and  surface  (8). 9. Subtract  distance  ‘D’  from  distance  ‘C’.   Result shall  not  be  more  than  0.375  inch.   If  more, perform  Tasks  11-7,  11-7.1,  and  11-9,  then 11-6.3. 10. Remove  scale  (1)  from  bolt  (6). INSPECT 11-23