TM  55-1520-240-23-8 10-16 TESTING REPAIRED  CELL — CHEMICAL (Continued) 10-16 NOTE Procedure  is same  for  testing  any  fuel cell.  Main  cell  is shown  here. 1. Install  fuel  cell  (1)  in  cage,  jig  or  overhead suspension  system  (2). 2. Install  plugs or  sealed  fittings  in  all  tank openings (3).   Leave  main  access door  (4)  and  one  tank opening  (5)  unsealed. 3. Install  tee  assembly (6)  in  tank opening  (5). 4. Connect  hose  (7)  from  air  supply to  one  leg  of tee  (6). 5. Connect  manometer  (8)  to  other  leg  of tee  (6). 6. Pour  114 cc  of  ammonium  hydroxide  (E73)  on cloth  (E120).   Wear  gloves  (E186). NOTE Wear  gloves through  rest  of task. 7. Insert  wet  cloth  into  fuel  cell  (1)  through  main access  (4). 8. Install  cover  plate  (9)  on  main  access  hole  (4). Install  screws (10)  and  washers (11). 9. Prepare  solution  of 40  grams  of phenolphthalein crystals  (E276)  and  2 quarts  of  ethyl  alcohol (E167).   Stir  solution  thoroughly. 10. Add  2 quarts  of  water  to  solution  and  stir. 11. Inflate  cell  (1)  with  dry  air  to  1  to 1.5  psi maximum. 12. Dip  cloth  (E120)  into  solution  and  wring  out  cloth thoroughly. 13. Spread  cloth  on  exterior  surface  of  cell  (1)  and press  cloth  to  ensure  contact with  surface.  Wait at  least  30  seconds. 10-66