TM  55-1520-240-23-8 10-16 TESTING  REPAIRED CELL —  CHEMICAL 10-16 INITIAL  SETUP Applicable Configurations: All Tools: Aircraft  Mechanic’s  Tool  Kit,  NSN  5180-00-323-4692 Overhead  Suspension  for  Fuel  Cell (Appendix  E-16) Tee  Fitting Manometer Source  of  Low  Pressure  Dry  Air Trip  Balance Graduate  (2000  cc) Open  Container,  2  Gallons Materials: Ammonium  Hydroxide  (E73) Cloths  (E120) Phenolphthalein  Crystals  (E276) Ethyl  Alcohol  (E167) Gloves  (E186) Personnel  Required: Medium  Helicopter  Repairer Inspector References: Task  10-2 Task  10-11 Task  10-12 Task  10-15 Equipment  Condition: Off  Helicopter  Task General  Safety  Instructions: Test  pressure  within  the  fuel coil  shall not  exceed  1.5 psi.   Damage  to  the cell  could  result  in  personal  injury  or death. Ethyl  alcohol is  flammable.  Use  only with  adequate  ventilation,  away  from heat  or open flame.  In case  of  contact, immediately  flush  skin  or  eyes  with water  for  at  least  15  minutes.  Get medical  attention  for  eyes. Ammonium  hydroxide  is  extremely toxic.   It  can  irritate  skin  and  cause burns.   Avoid  inhaling.  Use  only  with adequate  ventilation.  Avoid  contact with  skin,  eyes,  or  clothing.  In  case of  contact,  immediately  flush  skin or  eyes  with  water  for  at  least  15 minutes.   Get  medical  attention  for eyes. 10-65