TM  55-1520-240-23-8 10-15 REPAIR  FUEL CELL  INNER  LINER (Continued) 10-15 g. Apply  a  uniform  coat  of  barrier  cement (E63.3)  (4)  over  previous  coat  of  repair cement (2) to  within  no  more  than  1/4 inch  of repair  area  of  O.D.  Use  a  brush  (5).  Remove any  excess  cement from  unbuffed  area.  Use clean  cloth  (E120)  dampened  with  MEK (E244).  Wear gloves  (E184.1).  Allow  barrier to  dry  to  touch. h. Apply  a  second  coat  of  barrier  cement (E63.3)  (6)  over first  barrier  coat  (4) at  90º to  the  application  of  first coat.  Use  a  brush. Allow second  coat to  air dry for approximately 30  minutes. i. Prepare  repair cement  (E63.2) as  in  steps d  and  e. j. Carefully apply  a  thin  uniform  coat of cement mixture  (7) over  previous  coats  of  barrier cement  to  within  no  more  than  1/8  inch of  O.D.  of  buffed  edge  area.   Use  a  brush. Smooth  surface  with  MEK  (E244)  and remove  any  excess cement  from  unbuffed area.  Use  clean  cloth  (E120) dampened  with MEK (E244).  Wear gloves  (E184.1). Do  not  flex fuel cell  in  repair area. k. Allow finished  repair to  set  for  1 hour  before moving  fuel  cell. l. Allow finished  repair to  air  cure  for 24 hours at  room  temperature  of 70ºF (33ºC) minimum before  use. INSPECT FOLLOW-ON MAINTENANCE: Visually  inspect  repair  for  workmanship,  no  loose edges,  no  voids,  cement fully  cured. END  OF  TASK 10-59