TM  55-1520-240-23-8 10-12 REPAIR  FUEL CELL EXTERIOR  PLIES 10-12 INITIAL  SETUP Applicable Configurations: All Tools: Portable  Drill, Pneumatic,  NSN  5130-00-293-1978 Abrasive  Arbor,  1/4  Drive,  1  Inch  Diameter,  1  Inch Long,  Dunmore  Model  R421003  or Equivalent Materials: Cloths  (E120) Methyl-Ethyl-Ketone  (E244) Scotch-Brite  (E2) Repair Cement  —  2  Part  Set  (E63.2) Wooden  Tongue  Depressor (E424) Repair Fabric  (E170.1) Gloves  (E184.1  and  E186) Personnel  Required: Aircraft  Structural  Repairer Inspector References: None Equipment  Condition: As  Required General  Safety  Instructions: Methyl-ethyl-ketone  (E244) and  repair cement  (E63.2)  and  its  components are  flammable  and  toxic.   They can irritate  skin  and  cause  burns.   Use only  with  adequate  ventilation,  away from  heat  or  open  flame.   Avoid contact  with  skin,  eyes  or  clothing. In  case  of contact,  immediately  flush skin  or  eyes  with  water for  at  least 15 minutes.   Get  medical  attention for  eyes. 1. Repair hole  damage,  cuts,  tears,  and  snags that penetrate  outer coating  and  one  or more  exterior plies. a. Trim  away  loose, damaged  or blistered  outer coating  edges. a.1. Clean  damaged  area  using  a  clean  cloth dampened  with  MEK  (E244).  Wear  gloves (E184.1). 10-53