TM  55-1520-240-23-8 10-11 REPAIR  FUEL CELL OUTER  COATING (Continued) 10-11 b. Buff  surface  around  damage  3/4 inch  larger in  all  directions  than  damaged  area  (1).  Use portable  drill  (2),  abrasive  arbor,  and/or scotch-brite  (E2).  Buff  only  to  remove  gloss without  excessively  reducing  outer  coating thickness. c. Clean  buffed  area.  Use  a  clean  cloth  (E120) dampened  with  MEK  (E244).   Wear  gloves (E184.1). d. Prepare  repair  cement  (E63.2)  by  blending the  two  ingredients  of  part  2  (E63.5)  together first  and  then  transfer  the  entire  contents  of part  2  into  the  can  of  part  1  (E63.4).   Wear gloves  (E186). Unmixed  cement  will  not  cure. e. Stir  cement  mixture  with  tongue  depressor (E424)  for  approximately  5  minutes.  Make certain  components  are  completely  blended together. f. Carefully  apply  a  thin  uniform  coat  of  cement mixture  (3)  over  buffed  area  (4)  to  no  more than  1/4 inch  of  O.D.  of  buffed  area.   Use  a brush.   Smooth  surface  with  gloved  fingers wet  with  MEK  (E244).  Remove  any  excess cement  from  unbuffed  area.  Use  clean  cloth (E120)  dampened  with  MEK  (E244).   Wear gloves  (E184.1). Do  not  flex  fuel  cell  in  repair  area. g. Allow  finished  repair  to  set  for  1  hour  before moving  fuel  cell. h. Allow  finished  repair  to  air  cure  for  24 hours at  room temperature  of  70ºF (33ºC)  minimum before  use. INSPECT FOLLOW-ON  MAINTENANCE: Visually  inspect  repair  for  workmanship,  no  loose edges,  no  voids,  cement  fully  cured. END  OF  TASK 10-52